MOBOTIX M12
mx10-5-214-150 Enhanced Signal Out Options
Attribute
Value
Explanation
Signal Out Arming
Enable
Off
Activate Enhanced Signal Out
:
Enable
: activate Signal Out Action.
Off
: deactivate Signal Out Action.
Test Signal Output 1:
switch high
and
switch low
(no time table)
Weekdays_Mo-Fr
Weekend_Sa-So
Opening_Times
Closing_Times
MyCustomTimes
MxFallback
Time Table Profile
:
Time table profile for time-controlled signal out. (
Time Tables
)
Signal Out Properties
Signal Output 1
Signal Output Pin
:
Select output pin for enhanced signal out action (check
Manage Hardware Expansions
).
Note: make sure not to use the same output pin in
Signal Out Action
.
Off on Alarm
On on Alarm
Signal Output State
:
State of output pin on alarm. The initial value on camera start is the opposite state.
Switch Time
:
Switch Signal Output (pin 1-5) to High for [0..86000] seconds.
Dead Time
:
Timeout [0..3600 s] while detection is suspended.
Display Options
Show Event Symbols
:
Show Signal Out event symbols.
Illumination Filter
Illumination
Off
Greater
Less
Illumination Filter
:
Allow Signal Out actions, if illumination is greater/less than trigger level.
Level
:
Enter the level for illumination in lux.
Precision is one decimal digit.
Events for Signal Out
Passive Infrared Detector (PI)
PIR Enable
:
Motion detected by the infrared sensor.
PIR Level
:
Trigger level [0..100].
Video Motion Window (VM)
Video Motion Enable
:
Motion detection using digital image analysis.
Note:
parameters are taken from
Event Settings
.
Microphone (MI)
Microphone Enable
:
Noise detection using the internal microphone.
Note:
parameters are taken from
Event Settings
.
Signal Input (SI)
Signal Input
:
This event is triggered by an external signal (pin 9-5).
Select
Closed (low)
to trigger when loop connected to Signal Input is closed or
Open (high)
, when loop is opened.
Signal Input 1
Signal Input 2
Signal Input 3
Signal Input Pin
:
Select input pin for this event (check
Manage Hardware Expansions
).
Open (high)
Closed (low)
Rising (low to high)
Falling (high to low)
Change (Rising or Falling)
Trigger Condition
:
Select kind of trigger.
De-Bounce Time
:
De-Bounce time for signal input in ms [100..2000 ms].
Periodic Event (PE)
Periodic Event Enable
:
Trigger an action periodcally every x seconds.
Periodic Time Interval
:
Trigger interval [0..86400] in seconds.
Time Task (TT)
Time Task
:
Trigger an event using a
Time Task
.
User Click (UC)
User Click
:
Trigger an event if the corresponding button on the camera's web site is clicked.
Click here to trigger a
User Click
.
Buttons (BT)
Buttons Enable
:
Trigger an event by pressing button(s) on the camera body.
Announce network data
(during runtime) will by disabled by activating this event.
Right
Left
Right OR left
Right AND left
Button Combination
:
Select button(s) to trigger on.
IP Receive (RC)
IP Receive Enable
:
Event on receiving a message over the network.
Note:
parameters are taken from
Event Settings
.
COM In (CI)
COM In Enable
:
Trigger an event when receiving a message from the serial interface. Set interface to
Data > Terminal and Logger mode
.
Note:
parameters are taken from
Event Settings
.
Temperature (TP)
Temperature Enable
:
Trigger an event if the temperature is higher/lower than the temperature value set below.
Note:
parameters are taken from
Event Settings
.
Random Event (RD)
Random Event Enable
:
Activate random events.
Random event is evaluated on every live image.
Events per Hour
:
Set random level in events per hour. Valid range from 0.0001 to 500.0000.
Precision is up to four digits.